Chapter??燫F燤odule燙onfiguration
D7 (DIO7 Configuration) Command
<I/O Settings> The D7 command is used to
select/read the behavior of the DIO7 line (pin 12).
Options include:
" CTS flow control
" Analog-to-digital converter
" Digital input
" Digital output
D8 (DI8 Configuration) Command
<I/O Settings> The D8 command is used to
select/read the behavior of the DI8 line (pin 9).
This command enables configuring the pin to
function as a digital input. This line is also used
with Pin Sleep.
DA (Force Disassociation) Command
<(Special)> The DA command is used to immedi-
ately disassociate an End Device from a Coordi-
nator and reattempt to associate.
DB (Received Signal Strength) Command
<Diagnostics> DB parameter is used to read the
received signal strength (in dBm) of the last RF
packet received. Reported values are accurate
between -40 dBm and the RF module's receiver
sensitivity.
Absolute values are reported. For example: 0x58 = -88 dBm (decimal). If no packets have been
received (since last reset, power cycle or sleep event), 0 will be reported.
DH (Destination Address High) Command
<Networking {Addressing}> The DH command is
used to set and read the upper 32 bits of the RF
module's 64-bit destination address. When com-
bined with the DL (Destination Address Low)
parameter, it defines the destination address used
for transmission.
An module will only communicate with other
modules having the same channel (CH parame-
ter), PAN ID (ID parameter) and destination address
(DH + DL parameters).
To transmit using a 16-bit address, set the DH parameter to zero and the DL parameter less than
0xFFFF. 0x000000000000FFFF (DL concatenated to DH) is the broadcast address for the PAN.
Refer to the XBee/XBee-PRO Addressing section for more information.
AT Command: ATD7
Parameter Range:0 - 5
Parameter
Configuration
0
Disabled
1
CTS Flow Control
2
n/a
3
DI
4
DO low
5
DO high
Default Parameter Value:1
Parameters 3-5 supported as of firmware
version 1.x.A0
AT Command: ATD8
Parameter Range:0 - 5
(1, 2, 4 & 5 n/a)
Parameter
Configuration
0
Disabled
3
DI
Default Parameter Value:0
Minimum Firmware Version Required: 1.xA0
AT Command: ATDA
Minimum Firmware Version Required: v1.x80
AT Command: ATDB
Parameter Range [read-only]:
0x17-0x5C (XBee), 0x24-0x64 (XBee-PRO)
AT Command: ATDH
Parameter Range: 0 - 0xFFFFFFFF
Default Parameter Value: 0
Related Commands: DL (Destination Address
Low), CH (Channel), ID (PAN VID), MY (Source
Address)
相关PDF资料
XIB-E BOARD INTERFACE ETHERNET
XIB-R BOARD INTERFACE RS232/485
ZMN2400HPDB BOARD ROUTER DEV ZIGBEE 100MW
ZMN24HPDK-B KIT DEV W/ZIGBEE ZMN2400HP
ZNI1000TC IC TEMP SENSOR NI1000 SOT23-3
02110102-000 SNSR TILT RATIO 60DEG 500MA FLNG
1-5209285-2 FOPC BOA 12DB FC/UPC BP SM
2-1693560-0 BOA 20DB LC/UPC BB
相关代理商/技术参数
XBIB-U-DEV 功能描述:界面开发工具 USB XBee-PRO profes onal interface board RoHS:否 制造商:Bourns 产品:Evaluation Boards 类型:RS-485 工具用于评估:ADM3485E 接口类型:RS-485 工作电源电压:3.3 V
XBIB-U-SP 功能描述:界面开发工具 USB/Xbee/Xbee-Pro Inf Brd SMT Pads RoHS:否 制造商:Bourns 产品:Evaluation Boards 类型:RS-485 工具用于评估:ADM3485E 接口类型:RS-485 工作电源电压:3.3 V
XBIB-U-SS 功能描述:界面开发工具 USB/Xbee/Xbee-Pro Inf Brd SMT Skt RoHS:否 制造商:Bourns 产品:Evaluation Boards 类型:RS-485 工具用于评估:ADM3485E 接口类型:RS-485 工作电源电压:3.3 V
XBL6450BYFVR 制造商:Texas Instruments 功能描述:ECS BLUELINK - Tape and Reel
XBL6450YFHR 制造商:Texas Instruments 功能描述:
XBLYGK2 制造商:Schneider Electric 功能描述:INSERT LABELS FOR XBTGK2XXX
XBLYGK5 制造商:Schneider Electric 功能描述:INSERT LABELS FOR XBTGK5XXX
XBLYRT01 制造商:Schneider Electric 功能描述:Label inserts for XBTRT511